KB1463 - IzoT CT (OpenLNS CT) Product Information
IzoT Commisioning Tool (IzoT CT) is the latest LonMaker type product. OpenLNS CT was the first IzoT CT version.
We recommend that all new installations use the latest version of IzoT CT.
Information
Links:
Product Documentation (Data sheet):
https://www.enocean.com/en/product/izot-commissioning-tool/?ts=1699877960User’s Guides and Software downloads (software version readme file)
IzoT CT, OpenLNS CT, and LonMaker
IzoT CT User’s GuideLicense Wizard - installed automatically with CT.
Echelon License Wizard 1.00.105Do not install if using CT 4.5+, as it has this License Wizard version or a newer version.
CT 4.0 - 4.4
Use this version if you are using CT 4.0 - 4.4 with new CT Activation keys
Use if license Wizard shows PC offline even though the PC has internet access.
Tying a CT license to an email account. This allows you to see all licenses and do license recovery and returns. See link below on how to create an email account
Echelon License Wizard Email Account used for IzoT CT and IzoT Net ServerSoftware compatibility
Software Compatibility ListLNS Errors - Examples (NS, #88), (LNS, #7) and (DS, #200)
LNS run-time error list
Do not use the OpenLNS CT 4.0 OpenLNS Database validation tool as this may corrupt your database, upgrade to a newer CT version before using this tool.
Installation Information (details in IzoT CT User’s Guide):
IzoT CT runs on 32-bit and 64-bit Windows, but can only be used with 32-bit Office (32-bit Visio)
If you have 64-bit office (or 64-bit Visio) you will need to uninstall office (and Visio) and install 32-bit office, or use a Virtual Machine (VM) for CT.
Why is only 32-bit office (or 32-bit Visio) supported and not 64-bit office/Visio?
Almost all LNS device plug-ins are 32-bit applications. Since these 32-bit device plug-ins can not run on 64-bit office/Visio, CT only supports 32-bit Office/Visio.
IzoT CT uses Visio, and you can purchase Visio when you purchase CT.
If you purchase through a third-party, just run the latest CT installer.
Install Visio first then CT.
In this case you will have to activate Visio yourself.
If you purchased CT with Visio, Visio gets activated automatically.
For your first CT with Visio purchase, you will need to purchase the CT DVD with Visio
For all other purchases of CT with Visio, use the CT DVD with Visio that you initially purchase and purchase a CT with Vision Activation key for each additional PC.
Microsoft doesn’t allow us to provide Visio for CT as a downloadable link which is why you need to purchase a DVD.
If the DVD doesn’t have the latest CT then install only Visio from the DVD and then install the latest CT from the software downloads site.
Most Visio installation issues are resolved by using the latest CT version.
Visio has to be installed prior to installing CT (this is automatically handled when installing the DVD).
Use the latest version for all new installations
If you purchased a CT with Visio DVD, if the DVD is not the latest version (in November 2023 CT 4.5 was the latest) then do the following.
Install only Visio from the DVD, and then install latest CT from the EnOcean software downloads site.
Licenses
You need to purchase an Activation key to use CT
If you purchased the CT with visio DVD the Activation key will be on the DVD.
Visio will be automatically activated during the CT install process.
Otherwise an activation key will be sent to you.
CT comes with an one year maintenance license.
A valid maintenance license allows you to upgrade CT to a newer version.
You should purchase one or more one-year maintenance license for each CT PC.
You need to add maintenance licenses before the previous maintenance license expires.
Before the Maintenance license expires, you will get a pop up when you open CT.
If you purchased a maintenance license
contact edge.support@enocean.com after you activated CT and include a copy of the Purchase Order (PO)
Visio is required to use CT
If you purchased the CT with visio DVD then Visio will be automatically activated during CT installation.
If you purchased Visio separately then you need to activate Visio using the key you purchased.
Echelon License Wizard (Start > Echelon License Wizard > License Wizard)
Use to activate CT
Don’t use the “validate” or “upgrade” action as they don’t do anything
If you tie the CT Activation key to a Software download account then you can also do license return and recovery.
Echelon License errors
MachineLockRequirement
If using a VM, contact support and ask for a replacement MT license.
Contact support and as ask them to return the license or activation key.
BioLockFailed Machine Lock Mismatch
Some hardware, bios or software changed invalidating the license
You tried to open a copy of a license VM instead of the VM instance that you licensed
Contact support and as ask them to return the license or activation key
Send an email to edge.support@enocean.com if you have any license issues.
Please include screen shots of the error, and screen shot and text of the Activation key or license ID
How to activate CT
Run the Start > Echelon License Wizard > License Wizard
In step 1. click “Activate product Licenses”
You need to activate one CT license and one IzoT Net Server (or OpenLNS Server) license per PC
If your PC has internet access you should be able to activate CT automatically.
If you PC doesn’t have internet access or can’t communicate to the License server then you need to do offline activation
The Echelon License Wizard will create an *.elwrq file
There are two ways to process this file
Do it yourself - Use another PC with the Echelon License Wizard with internet access
In the Echelon License wizard step 1, click the yellow “Show Advanced Tasks”
Select the first task “Process a license request file created on another computer” and complete the process
Send the *.elwrq file to EnOcean at edge.support@enocean.com
EnOcean will then send you an activation response file *.elwrs
Activate CT PC - Once you have the *.elwrs file
Go back to the original PC and in step 1 in the License Wizard, click the yellow “Show Advanced Tasks”
Select the second task “Process a license response file obtained from Echelon” and complete the process
Making sure your network continues to work:
Make backups before and after any changes
Save this on another PC in case the PC goes down.
Making sure the CT network has no issues -
run database validation and drawing-to-database synchronisation.backup the network
Use the OpenLNS Database Validation tool to check and fix LNS database issues
The tool can fix many issues but not all.
In CT, do drawing to database synchronisation to make sure the CT drawing is in sync with the LNS database.
Backup any changes.
Only create devices types in CT using a XIF file.
Creating a device type by using upload from device may work initially but may stop working at a later date.
Restoring a previously created LonMaker, OpenLNS CT or IzoT CT network:
Backup Restore examples:
A backed up network database can be restored on a newer version
Backed up LonMaker network databases can be restored on IzoT CT
OpenLNS CT or IzoT CT 4.4 database can be restored on a IzoT CT 4.5 PC
A backed up network database can not be downgraded to an older version
IzoT CT backed up network databases can not be restored on LonMaker PCs
IzoT CT 4.5 database can not be restored on LonMaker, OpenLNS CT or IzoT CT 4.4.
Restore a backed up network Instructions:
On the old PC, backup the older network database
On the old PC with LonMaker (ignore this step if the old PC has OpenLNS CT or IzoT CT)
Fix any database or drawing issueRun database validation tool to find and fix any database issues.
fix any issues and re-run until no errors.
Make a backup.
In LonMaker or CT, run drawing to database synchronisation.
fix any issues and re-run until no errors.
Make a backup
On the new PC with IzoT CT
restore the backed network
Run database validation tool to find and fix any database issues.
Start > Echelon IzoT Network Services Utilites >OpenLNS Database Validation ToolMake a backup.
In CT, run Add-ons > Synchronization > Resynchronization
Select drawing to database synchronisation and run validation.
Make a backup
Related Products
IzoT CT
OpenLNS CT